Witryna3 sie 2024 · 2004 - 2008 Ford F150 - 5.4 3V IMRC (intake manifold runner control) - Hi guys i need help, i have a 2004 Ford F150 5.4 3V, after getting my engine repaired i took it for a test drive and got my CEL on it was a P2006 IMRC Stuck Closed Bank 1 so my mechanic went ahead and replace the IMRC with a Dorman ( i couldn't... WitrynaIf your OBD II equipped vehicle has stored a code P2006, it means that the powertrain control module (PCM) has detected that the intake manifold air control (IMRC) actuator for engine bank one is stuck in the closed position. Bank 1 indicates that the malfunction is related to the bank of the engine that contains the number one cylinder.
5.4 3V IMRC (intake manifold runner control) - F150 Forum
WitrynaP2004 - Intake manifold runner control (IMRC) stuck open (bank 1) Description - This DTC is set when the IMRC is commanded closed, but the IMRC monitor indicated open. This DTC replaces P1518 and P1537. Probable causes - IMRC monitor signal circuit shorted to PWR GND or SIG RTN - Damaged IMRC actuator or solenoid - Blocked … WitrynaAbove approximately 3000 rpm, the vacuum solenoid will be de-energized. This will allow a vacuum to vent from the actuator and the butterfly valve plates to open. The Diagnostic Trouble Code (DTC) sets when the IMRC is commanded open, but the IMRC monitor indicates close. P2006 Ford Code - Intake Manifold Runner Control Stuck Closed … simply southern application
Intake Manifold Runner Valves: What You Need to Know - In
Witryna1 lut 2011 · I'll try to see if a PCM codes have been predefined for a IMRC being stuck close position. Maybe the IMRC is sending the correct signal to the PCM but the linkage is broken inside, the sound of a broken or stripped gear --> squeal like a pig sound.:shiny: Looking at attached PDF file it looks like it's possible to do a beach test on the IMRC. Witryna8 wrz 2024 · When there is a feedback mechanism and the ECM/PCM detects that the IMRC actuator doesn’t respond to the command to open or close, a code will be set. … Witryna3 sie 2024 · (screwy 'upside-down' formula), -128 = closed, Formula for Degrees open from 0 to 90 is: INT(50.4+((100/255)*Signed(A)+Signed(B)))). There is a 'IMRC (Swirl … ray west brownwood tx